EMS Technical Documentation
2026.9.1
1. Internet connection
A permanent internet connection for EMS is recommended. In principle, offline operation is also possible. In this case, however, the following functions cannot be used:
-
System updates
-
Installation of new EMS apps
-
Transmission of measurement data to Heckert Solar server for remote access
-
Use of Online Monitoring via the Heckert Solar portal access (e. g. on the go via smartphone)
-
Maintenance access for FENECON service employees
-
Use of EMS apps with third-party services via the internet (e. g. Time-of-use tariffs)
2. Network configuration
In the standard configuration, the EMS obtains the IP address via a DHCP server (e. g. FritzBox). The network configuration can also be adjusted in Online Monitoring under Settings → Network configuration. More information can be found here.
3. Firewall
The following services are active on the EMS and require an Internet connection to the respective target addresses and ports.
| Service | Destination Address(es) | Destination Port |
|---|---|---|
DNS |
(IP address of the DHCP-assigned |
53 (DNS) |
Online Monitoring |
144.76.42.217 (fenecon.de) |
443 (HTTPS) |
Time Synchronization |
144.76.42.217 (fenecon.de) |
123 (NTP) |
Operating System Package Updates |
144.76.42.217 (deb.fenecon.de) |
80 (HTTP) |
Remote Maintenance |
168.119.5.99 (remote-service.fenecon.de) |
2222 |
Heckert Solar Service |
185.145.190.0/24 |
|
If you have problems with any of these steps, please check the port release of the router or contact service@fenecon.de. |
4. API Communication
Some Symphon-E Apps may require additional access, e. g.:
-
Symphon-E App Time-of-Use Tariff to access Entso-E (
web-api.tp.entsoe.eu). -
Symphon-E App Weather to access weather data (
customer-api.open-meteo.com). -
Symphon-E App clever-PV to access the clever-PV Connect API (https://connect.docs.clever-pv.com/introduction).
5. System update
The EMS is regularly updated as part of software updates.
These updates can be installed via the Settings → EMS system update tab.
6. Interaction with Other EMS Systems
|
General note on the functionality of EMS in connection with other Energy Management Systems: There is a possibility that unwanted interactions may occur if another EMS is installed alongside EMS. To ensure that the EMS functions optimally, even when used in connection with hardware components from other manufacturers, no other EMS must be installed on the system at the same time. |